ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V ≤ VPWR ≤ 20 V, 3.0 V ≤ VDD ≤ 5.5 V, -40 °C ≤ TA ≤ 125 °C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
OUTPUTS HS0 TO HS3 (continued)
Current Sense Ratio (CSR0) Accuracy (6.0 V < VHS < 20 V)
with 28 W bit=1
Output Current
3.0 A
1.5 A
CSR0_1_ACC
-16
–
-20
–
%
16
20
CSR0 Current Recopy Accuracy with one calibration point (6.0 V < VHS[0:3] <
20 V)(17)
CSR0_0_ACC(
CAL)
-5.0
–
Output Current
5.0 A
CSR0 Current Recopy Temperature Drift (6.0 V < VHS[0:3] < 20 V)
with 28 W bit=0(18)
Δ(CΔS(RT0)_0)/
Output Current
5.0 A
5.0
%
%/°C
0.04
Current Sense Ratio (CSR1) Accuracy (6.0 V < VHS[0:3] < 20 V)
with 28 W bit=0
Output Current
12.5 A
75 A
CSR1_0_ACC
-17
–
-12
–
%
+17
+12
Current Sense Clamp Voltage
CSNS Open; IHS[0:3] = 5.0 A with CSR0 ratio
OFF Open-load Detection Source Current(19)
OFF Open-load Fault Detection Voltage Threshold
ON Open-load Fault Detection Current Threshold
ON Open-load Fault Detection Current Threshold with LED
VHS[0:3] = VPWR - 0.75 V
Output Short to VPWR Detection Voltage Threshold
Output programmed OFF
Output Negative Clamp Voltage
0.5 A < IHS[0:3] < 5.0 A, Output programmed OFF
VCL(CSNS)
VDD+0.25
V
VDD+1.0
IOLD(OFF)
30
–
100
μA
VOLD(THRES)
2.0
3.0
4.0
V
IOLD(ON)
100
300
600
mA
IOLD(ON_LED)
2.5
5.0
mA
10
VOSD(THRES)
V
VPWR-1.2 VPWR-0.8 VPWR-0.4
VCL
- 22
–
V
-16
Output Over-temperature Shutdown for 4.5 V < VPWR < 28 V
TSD
155
175
195
°C
Notes
17. Based on statistical analysis. It is not production tested.
18. Based on statistical data: delta(CSR0)/delta(T)={(measured ICSNS at T1 - measured ICSNS at T2) / measured ICSNS at room} / {T1-T2}. No
production tested.
19. Output OFF Open-load Detection Current is the current required to flow through the load for the purpose of detecting the existence of
an open-load condition when the specific output is commanded OFF. Pull-up current is measured for VHS=VOLD(THRES)
Analog Integrated Circuit Device Data
Freescale Semiconductor
10XS3412
11