datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

A43L2616V-75I 查看數據表(PDF) - AMIC Technology

零件编号
产品描述 (功能)
比赛名单
A43L2616V-75I
AMICC
AMIC Technology AMICC
A43L2616V-75I Datasheet PDF : 42 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
A43L2616B
Operating AC Parameter
(AC operating conditions unless otherwise noted)
Symbol
Parameter
tRRD(min)
tRCD(min)
Row active to row active delay
RAS to CAS delay
Version
-6
-7
12
14
18
20
Unit
Note
ns
1
ns
1
tRP(min)
tRAS(min)
tRAS(max)
tRC(min)
Row precharge time
Row active time
Row cycle time
18
20
ns
1
42
42
ns
1
100
μs
60
63
ns
1
tCDL(min) Last data in new col. Address delay
tRDL(min) Last data in row precharge
tBDL(min) Last data in to burst stop
tCCD(min) Col. Address to col. Address delay
Number of valid output data
CAS Latency = 3
CAS Latency = 2
6
7
ns
2
12
14
ns
2
6
7
ns
2
6
7
ns
2
ea
3
1
Note: 1. The minimum number of clock cycles is determined by dividing the minimum time required with clock cycle time and
then rounding off to the next higher integer.
2. Minimum delay is required to complete write.
3. In case of row precharge interrupt, auto precharge and read burst stop.
(December, 2009, Version 1.3)
7