datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

W49F201T-55B 查看數據表(PDF) - Winbond

零件编号
产品描述 (功能)
比赛名单
W49F201T-55B
Winbond
Winbond Winbond
W49F201T-55B Datasheet PDF : 23 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Preliminary W49F201
Command Codes for Word Program
WORD SEQUENCE
0 Write
1 Write
2 Write
3 Write
ADDRESS
DATA
5555H
AAH
2AAAH
55H
5555H
A0H
Programmed-address
Programmed-data
Pause 50 µS
Word Program Flow Chart
Word Program
Command Flow
Load data AA
to
address 5555
Load data 55
to
address 2AAA
Load data A0
to
address 5555
Load data Din
to
programmed-
address
Pause 50 µS
Exit
Notes for software program code:
Data Format: DQ15DQ8: Don't Care; DQ7-DQ0 (Hex)
Address Format: A14A0 (Hex)
*It is not allowed to assert read command during the 4-word command sequence(program).
To assert the read command during the 4-word command sequence will abort programming procedure.
Publication Release Date: June 1999