datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MP7641AS 查看數據表(PDF) - Exar Corporation

零件编号
产品描述 (功能)
比赛名单
MP7641AS Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MP7641
8085
ALE
WR
SOD
8
8
8212
8
ADDRESS BUS
+5
E1
E3
E2
3
A0 to A2
74LS138
ADDRESS
DECODER
DATA BUS
LD
SDI
CLK
MP7641
RST
FROM SYSTEM RESET
Figure 6. 8085 Interface (Simplified Diagram)
NOTES:
1. Clock generated by WR and decoding address 8000
2. Data is clocked into the DAC shift register by executing memory write instructions. the clock input is
generated by decoding address 8000 and WR. Data is then loaded into the DAC register with a memory
write instruction to address 4000.
3. Serial data must be present in the right justified format in registers H & L of the microprocessor.
Rev. 2.00
11

Share Link: 