AC SPECIFICATIONS
Parameter
Clock Cycle Time
Input Setup Time
Clock to Input Invalid (Input Hold)
Clock to Output Driven
Clock to Output Valid
Clock to Output Invalid
Clock to Output High–Z
Timing
Reference
MPC2605–66
Min
Max
15
—
4.5
—
2
—
2
9
2
9
2
—
2
12
Unit Notes
ns
ns
1
ns
1
ns
2
ns
ns
2
ns
2
PWRDN Disable to Recovery
—
4
µs
2
NOTES:
1. All input specifications are measured from the TTL level (0.8 or 2.0 V) of the signal in question to the 1.4 V level of the rising edge of the input
clock. Both input and output timings are measured at the pin.
2. This parameter is sampled and not 100% tested.
CLK
INPUTS
OUTPUTS
MPC2605
8