DC ELECTRICAL CHARACTERISTICS 1 (CON"T)
SYMBOL
PARAMETER
CONDITION
MIN
MAX UNIT
Supply Current
ICCL
Total Supply Current
RL = 35Ω
END, ENCK= VDD, VDD= 3.6V
220
ma
ICCZ Tri-State Supply Current
END, ENCK = VSS, VDD= 3.6V
20
ma
Notes:
1. Current into device pins is defined as positive. Current out of device pins is defined as negative. All voltages are referenced to ground.
2. Output short circuit current (IO S) is specified as magnitude only, minus sign indicates direction only. Only one output should be shorted at a time, do not exceed
maximum junction temperature specification.
3. Guaranteed by characterization.
7