datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MB3802 查看數據表(PDF) - Fujitsu

零件编号
产品描述 (功能)
比赛名单
MB3802 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
5. Connecting Parallel Switches
DLYA
DCGA
VINA
VINB
SWINA
SWOUTA
GND
SWINB
SWOUTB
DLYB
DCGB
Load
MB3802
VS
3 V to 5 V
Note: Connect the circuits A and B in parallel to produce a low ON resistance (RON = 0.06 ).
In this case, connect the DLYA and DLYB pins in common to give synchronous ON/OFF
between both switches.
6. 25% ON Resistance
DCGA
VINA
VINB
VINA
VINB
DLYA
SWINA
SWOUTA
SWINB
DLYB
SWOUTB
GND DCGB
DLYA
DCGA
SWINA
SWOUTA
SWINB
DLYB SWOUTB
GND DCGB
Load
VS
3 V to 5 V
Notes:
1. Make this connection to produce an ON resistance that is much lower than the above connection.
Also, connect the DLY pins in common.
2. Consider the difference between the ON resistances and the switch-ON/OFF times between two
devices (MB3802) and insure that load control is not offset at one device.
9