4.3. Test methodology
4.3.1. Filter insertion loss and attenuation and return loss test :
4.3.1.1. Test equipment :
a : HP4395A Network / Spectrum / Impedance Analyzer
b : HP87512A Transmission / Reflection test set
c : Balun North Hills : 0303LB( 50Ω : 135Ω ) / 0415LB( 50Ω : 150Ω )
4.3.1.2. Test Setup: is shown in Fig.1 .
4.3.1.3. Test procedure : 1
a : Set HP4395A in B/R mode for insertion loss and attenuation test while in A/R
mode for Return loss test.
b : Connecting the Analyzer to the ISDN and LINE sides of splitters through the North
Hills Balun 0303LB/ 0415LB
c : Set frequency of interest given in specification.
d : Calibrating the HP4395A network Analyzer via the thru for attenuation test while
open, short, load calibration being performed for Return loss.
e : Measurement insertion loss and attenuation and Return loss.
Filter
Fig.1. Test Setup
Data sheet subject to change without notice
41.8nF
82uH
41.8nF
Fig.1-a ZADSL Load
RDPS-POTS418(R1)10/17/2002