Product Specification
4.3.2. Filter insertion loss test for POTS port :
CPF104IG
The insertion loss of a device connected into a given transmission system is defined as the
ratio, expressed in dB, of the load power available(before and after insertion ) delivered to
the output network beyond the point of insertion at a given frequency. In general , the
insertion loss of a device inserted in a given transmission system mainly caused by internal
component resistive loss while all of the impedance between source , load and device
interface having been matched. To perform the insertion loss measurement ,thru calibration
must be done prior the testing . General Insertion loss equation can be expressed as
following.
Insertion loss = 20 log V2 / V1dB where
V1 = the measured voltage value of load without LPF in circuit.
V2 = the measured voltage value of load with LPF in circuit.
The test setup is shown in drawing below. :
600ohm
600ohm
ZADSL
Data sheet subject to change without notice
RDPS-POTS434(R0)10/16/2002
SHEET 8 OF 11