LC72E32
Continued from preceding page.
Operand
Mnemonic
1st 2nd
Function
LCD
LCP
IN
OUT
SPB
RPB
TPT
TPF
Output segment pattern
M
I to LCD digit direct
Output segment pattern
M
I to LCD digit through PLA
M P Input port data to M
M P Output contents of M to port
P N Set port bits
P N Reset port bits
Test port bits,
P N then skip if all bits
specified are true
Test port bits,
P N then skip if all bits
specified are false
Operation
LCD (DIGIT) M
LCD (DIGIT) PLA M
M (Port (P))
(Port (P)) M
(Port (P)) N 1
(Port (P)) N 0
if (Port (P)) N = all 1s,
then skip
if (Port (P)) N = all 0s,
then skip
UCS
I
Set I to UCCW1
UCCW1 I
Machine code
D15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 D0
1 1 1 0 0 0 DH
DL
DIGIT
1 1 1 0 0 1 DH
DL
1 1 1 0 1 0 DH
DL
1 1 1 0 1 1 DH
DL
1 1 1 1 0 0 00
P
1 1 1 1 0 1 01
P
DIGIT
P
P
N
N
1 1 1 1 1 0 10
P
N
1 1 1 1 1 1 11
P
N
0 0 0 0 0 0 01 0000
I
UCC
I
FPC
N
CKSTP
DAC
I
NOP
Set I to UCCW2
F port I/O control
Clock stop
Load M to D/A registers
No operation
UCCW2 I
FPC latch N
Stop clock if H O L D = 0
DAreg DAC DATA
0 0 0 0 0 0 11 0000
I
0001
0001
0000
0000
0 0 00 0000
N
0 0 01 0000 000 0
0 0 10 0000
I
0 0 00 0000 000 0
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customers
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customers products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products (including technical data, services) described or contained
herein are controlled under any of applicable local export control laws and regulations, such products must
not be exported without obtaining the export license from the authorities concerned in accordance with the
above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the Delivery Specification
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of September, 1998. Specifications and information herein are
subject to change without notice.
PS No. 4741-15/15