GS88218/36BB/D-333/300/250/200/150
Operating Currents
-333
-300
-250
-200
-150
Parameter Test Conditions
Mode
Symbol 0 –40 0 –40 0 –40 0 –40 0 –40 Unit
to to to to to to to to to to
70°C 85°C 70°C 85°C 70°C 85°C 70°C 85°C 70°C 85°C
Operating
Current
Pipeline
(x32/
IDD
IDDQ
250
40
270
40
230
35
250
35
200
30
220
30
170
25
190
25
140
20
160
20
mA
Device Selected;
All other inputs
x36)
Flow
Through
IDD
IDDQ
205
25
225
25
185
25
205
25
160
25
180
25
140
20
160
20
130
15
150
15
mA
≥VIH or ≤ VIL
Output open
Pipeline
IDD
IDDQ
230
20
250
20
210
20
230
20
185
15
205
15
155
15
175
15
130
10
150
10
mA
(x18)
Flow
Through
IDD
IDDQ
185
15
205
15
170
15
190
15
145
15
165
15
130
10
150
10
120
8
140
8
mA
Pipeline
ISB
40 50 40 50 40 50 40 50 40 50 mA
Standby
Current
ZZ ≥ VDD – 0.2 V
—
Flow
Through
ISB
40 50 40 50 40 50 40 50 40 50 mA
Device Deselected;
Pipeline
IDD
95 100 90 95 85 90 75 80 60 65 mA
Deselect
Current
All other inputs
≥ VIH or ≤ VIL
—
Flow
Through
IDD
65 60 60 65 60 65 50 55 50 55 mA
Notes:
1. IDD and IDDQ apply to any combination of VDD3, VDD2, VDDQ3, and VDDQ2 operation.
2. All parameters listed are worst case scenario.
Rev: 1.02 10/2004
18/37
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
© 2002, GSI Technology