datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MM1288CQ 查看數據表(PDF) - Mitsumi

零件编号
产品描述 (功能)
比赛名单
MM1288CQ Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
MITSUMI
TFT Liquid Crystal Interface MM1288CQ
Item
Sub-bright input current
Symbol
I20, I38
COMMON DC VOLT input current I21
COMMON INV threshold voltage VTH24
COMMON INV input current
I24
COMMON SWING input current I26
GAMMA1 input voltage
I32
GAMMA2 input voltage
I35
INV threshold voltage
INV input current
Contrast input current
Bright input current
CENTER DC input current
VTH36
I36
I39
I42
I35
SW threshold voltage
VTH47
SW input current
GAMMA1 fluctuation
I43
V34
GAMMA2 fluctuation
V39
H-to-L common transport delay time tPHL
L-to-H common transport delay time tPLH
COMMON fall time
tTHL
COMMON rise time
tTLH
Difference in COMMON
tT
rise and fall times
H-to-L primary color signal
tPHL
transport delay time
L-to-H primary color signal
tPLH
transport delay time
Primary color signal fall time
tTHL
Primary color signal rise time
tTLH
Difference in primary color
tT
signal rise and fall times
Measurement conditions
SW21, 42, 46 ; B
Measure I21 and 42 when V21 and 42 are 7.5V and 10.5V.
SW22 ; B
Measure I22 when V22=0V.
SW26 ; B
Vary V26 between 0~13V and measure
V26 when T27 phase inverts.
SW26 ; B
Measure I26 when V26=0 and 13V.
SW28 ; B
Measure I26 when V26=9 and 12V.
SW34 ; B
Measure I34 when V34=11V.
SW39 ; B
Measure I39 when V39=1V.
Vary T40 voltage from 0 5V and measure
the voltage when T27 phase inverts.
Measure I40 when V40 is 0V.
SW43 ; B
Measure I43 when V43 is 0.5V and 4.5V.
Measure I46 when V46=1.7V.
Measure I35 when V35=VCC2
SW2~4, 47 ; B, T2~4 ; SG3
Adjust V46 so that T29, 31 and 33
amplitude is 8V. Vary V47 voltage from
0 5V and measure V47 when T29, 31
and 33 sine waves disappear.
SW47 ; B Measure I47 when V47=0V.
SW2~4, 34, 43 ; B, T2~4 ; SG5
Adjust V43 so that T29, 31 and 33 amplitude is
3V. Vary V34 voltage from 3 6V and measure
the amount of T29, 31 and 33 voltage change.
SW2, 3, 4, 39, 43 ; B, T2~4 ; SG5
Adjust V43 so that T29, 31 and 33 amplitude is
3V. Vary V39 voltage from 6.2 8V and measure
the amount of T29, 31 and 33 voltage change.
SW27, 28 ; B, T40 ; SG6
Adjust V28 so that T27 amplitude is 6V.
tT= tTHL-tTLH
SW29, 31, 33 ; B, T40 ; SG6
Adjust V46 so that T29, 31 and 33
amplitude is 8V.
tT= tTHL-tTLH
Min. Typ. Max. Units
-50
40 µA
-100
µA
6.0 6.5 7.0 V
-90
90 µA
-60
60 µA
6 µA
-6
µA
2.5 3.0 3.5 V
-2
µA
-60
70 µA
3 µA
105 110 165 µA
0.8 1.4 2.0 V
4.5 µA
0.8 1.2 2.1 V
0.8 1.2 2.1 V
2 µS
2 µS
2 3 µS
2 3 µS
2 µS
2 µS
2 µS
1 2 µS
1 2 µS
1 µS