DSX–1 ISOLATED PULSE TEMPLATE Figure 3
1.0
0.5
NORMALIZED
ALITITUDE
0.0
DS2186
–0.5
0
250
500
750
1000
1250
NANOSECONDS
NOTES:
1. Template shown is measured at the cross–connect point.
2. Amplitude shown is normalized; the actual midpoint voltage measured may be between 2.4 and 3.6 volts.
3. The corner points shown below are joined by straight lines to form the template.
MAXIMUM CURVE
(0, 0.05)
(250, 0.05)
(325, 0.80)
(325, 1.15)
(425, 1.15)
(500, 1.05)
(675, 1.05)
(725, –0.07)
(875, 0.05)
(1250, 0.05)
MINIMUM CURVE
(0, –0.05)
(350, –0.05)
(350, 0.5)
(400, 0.95)
(500, 0.95)
(600, 0.9)
(650, 0.5)
(650, –0.45)
(800, –0.45)
(925, –0.2)
(1100, –0.05)
(1250, –0.05)
022798 5/11