Characteristics
Zelio Relay plug-in relays
0
Miniature relays
Relay type
Contact characteristics
Number and type of contacts
Contact materials
Rated conventional
thermal current (Ith)
For temperature T 40°C
Maximum operating rate
In operating cycles/h
No-load
Under load
Switching voltage
Minimum
Maximum
Maximum breaking capacity
RXL 2A12BGGG
2 C/O
(AgNi)
A 12
18 000
1200
V5
V 4 400, 6 250
VA 3000
RXL 3A10BGGG
3 C/O
10
2500
RXL 4A06BGGG
4 C/O
6
1500
RXL 4G06BGGG
AgNI/AU 0.2 µ
Coil characteristics
Rated voltage (Un)
Average consumption
Permissible voltage variation
Drop-out voltage threshold
Environment
Conforming to standards
Approvals (pending)
Ambient air temperature
around the device
Vibration resistance
Degree of protection
Shock resistance
Mechanical durability
Operating time
(response time)
Electrical durability
In millions of operating cycles/h
4 V 24…230, 50/60 Hz
6 V 12…110
4 VA 1.6
6 W 0.9
0.8…1.1 Un (50/60 Hz or 6)
4
0.15 Un
6
0.1 Un
Standard version
Standard version
Storage
°C
Operation
°C
To IEC 68-2-6
In millions of operating cycles
Between coil
energisation and
making of the
On-delay contact
4 ms
6 ms
Between coil
4 ms
de-energisation and 6 ms
making of the
Off-delay contact
Resistive load
Inductive load
IEC 61810-1
UL, CSA
- 40…+ 85
6 - 40…+ 70, 4 - 40...+ 55
> 5 gn (10…150 Hz)
IP 40
10 gn (closing), 5 gn (opening)
20
About 12
About 12
About 12
About 4
12 A - 250 V: 0.1 10 A - 250 V: 0.1
See curves below
20
6 A - 250 V: 0.1
Insulation characteristics
Rated insulation voltage (Ui)
Conforming to IEC 947
Insulation class
Dielectric strength
(rms voltage)
Conforming to VDE 0110
Between coil and
4
contact
Between poles
Between contacts
4
Electrical durability of the contacts
Resistive load 4
107
C
106
A
105
0
1
B
2
3
Switching capacity
A RXL 4
B RXL 2
C RXL 3
V 250
C 250
V 2500
B 250
V 2500
V 1500
Reduction coefficient for inductive load 4
(depending on power factor cos ϕ)
1
0,8
0,6
2000
Maximum switching capacity on a resistive
$load 6
12
10
5
4
3
0,4
1 0,8 0,6 0,4
0,3
0,2
Cos ϕ
2
C
1
0,5
0,4
0,3
D
A
0,2
0,1
B
0 20 30 80 120 160 200 250 300
VoltageÃ6
RXL 2, RXL 3 and RXL 4
A RXL 3 (T = 0 ms)
B RXL 3 (T = 40 ms)
C RXL 4
D RXL 2
Durability (inductive load) = durability (resistive load) x reduction coefficient