NCL30000
Table 1. PIN FUNCTION DESCRIPTION
Pin Name
Function
1
MFP The multi-function pin is connected to the internal error amplifier. By pulling this pin below the Vuvp threshold, the
controller is disabled. In addition, this pin also has an over voltage comparator which will disable the controller in the
event of a fault.
2 COMP The COMP pin is the output of the internal error amplifier. A compensation network is connected between this pin
and ground to set the loop bandwidth. Normally this bandwidth is set at a low frequency (typically 10 Hz 20 Hz) to
achieve high power factor and low total harmonic distortion (THD).
3
Ct
The Ct pin sources a regulated current to charge an external timing capacitor. The PWM circuit controls the power
switch on time by comparing the Ct voltage to an internal voltage derived from VControl. The CT pin discharges the
external timing capacitor at the end of the on time cycle.
4
CS
The CS input is used to sense the instantaneous switch current in the external MOSFET. This signal is filtered by an
internal leading edge blanking circuit.
5
ZCD The voltage of an auxiliary zero current detection winding is sensed at this pin. When the ZCD control block circuit
detects that the winding has been demagnetized, a control signal is sent to the gate drive block to turn on the
external MOSFET.
6
GND This is the analog ground for the device. All bypassing components should be connected to the GND pin with a short
trace length.
7
DRV The high current capability of the totem pole gate drive (+0.5/0.8 A) makes it suitable to effectively drive high gate
charge power MOSFETs. The driver stage provides both passive and active pull down circuits that force the output to
a voltage less than the turn-on threshold voltage of the power MOSFET when VCC(on) is not reached.
8
VCC This pin is the positive supply of the controller. The circuit starts to operate when VCC exceeds VCC(on), nominally
12 V and turns off when VCC goes below VCC(off), typically 9.5 V. After startup, the operating range is 10.2 V up to
20 V.
AC
Line
Input
EMI
FILTER
C in
RSU
ÏÏD1
R1
R ZCD
NCL30000
1 MFP
VCC 8
Q1
C1
2 COMP
DRV 7
R2
Ccomp
3 CT
GND 6
Ctim
4 CS
ZCD 5
R CS
ÏDout
Ra
Cv
8
VCC
RL
OUT2
Ï7
IN2+ 5
+
IN26
ÏÏ NCS1002
ÏÏ OUT1
IN12
1
+ IN1+ 3
Rb Rx
Rt
GND
4
Ry
Cc
C OUT
Rc
RLED
Figure 2. Simplified Flyback Application with Secondary side Constant Current Control