datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

LVA519 查看數據表(PDF) - Mitsumi

零件编号
产品描述 (功能)
比赛名单
LVA519 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
MITSUMI
Sync Separator with AFC LVA519
Measuring Procedures (Except where noted otherwise, Ta=25°C, VCC=5.0V, VIN=2.0VP-P)
Item
Switch state
Symbol
S1 S2 S3 S4 S5
Measuring Procedures
Consumption current Id B B A A A Connect a DC ammeter to VCC pin.
Horizontal sync (H) VHH B A B B A Input standard color bar 2VP-P.
output
(L) VHL B A B B A Measure at TP5
Vertical sync (H) VVH B A B B A Input standard color bar 2VP-P.
output
(L) VVL B A B B A Measure at TP4.
Free-running frequency
fO
setting range
A B B B A Adjust VR1 and measure frequency at TP5.
Power supply fluctuation of
free-running frequency
With fo at 15.73kHz, vary Vcc between 4.0V~6.0V
fO1 A B B B A
and measure at TP5.
Free-running frequency
temperature coefficient
With fo at 15.73kHz, vary temperature between
fO2 A B B B A
-20°C and 80°C and measure at TP5.
Capture range
* fC B/A A B B A Input standard color bar 2VP-P and measure at TP1 and TP5. 1
Lock range
* fL B/A A B B A Input standard color bar 2VP-P and measure at TP1 and TP5. 1
* AFC output delay time td A/B A B B A Input standard color bar 2VP-P and measure at TP2 and TP5. 2
* AFC output pulse width Pw A/B A B B A Input standard color bar 2VP-P and measure at TP5. 2
Schmitt trigger
threshold
(H) VtHH
* B A B B A Measure at TP3 and TP4. 3
(L) VtHL
Measuring Procedures (Except where noted otherwise, Ta=25°C, VCC=5.0V, VIN=2.0VP-P)
Item
Symbol
S1
Sync separation
VSEPA B
level
AFC switching
RAFC B
resistance
Switch state
S2 S3 S4
ABB
ABB
Measuring Procedures
S5
Raise horizontal sync signal level of input standard
A color bar 2VP-P and measure the level when a signal
is output at TP5.
With Fo at 15.73kHz, vary Iafc, and determine
according to Iafc value when TP5 output signal
B
switches to a composite signal, and TP6 voltage V6.
RAFC=V6/IA1
Notes:
*1 Capture range (fc)
15.73KHz
Vary VR1 between max min and min max with SW1, and for each
lock make SW1 A and measure at TP5.
fc1
fc2 Data : fC1 and fC2 smaller value
Lock range (fL)
15.73KHz
fL1
fL2
With SW1 at B and locked, vary VR1 and when the lock is released,
make SW1 A and measure at TP5.
Data : fL1 and fL2 smaller value