Light-Management IC with Efficient 1x/1.5x/2x
Charge Pump for Backlight/Flash/RGB LEDs
ELECTRICAL CHARACTERISTICS (continued)
(VIN = VPIN = VDD = 3.6V, VGND = VPGND = 0V, temperature derating disabled, TA = -40°C to +85°C, typical values are at TA =
+25°C, unless otherwise noted.) (Note 1)
PARAMETER
Input Voltage Mode Transition Hysteresis
M_, S_, F_ Leakage in Shutdown
OUT Pulldown Resistance in Shutdown
Maximum OUT Current
Open-Loop OUT Resistance
Switching Frequency
S1, S2, S3 (RGB) Full-Scale Ramp Time
Logic-Input High Voltage
Logic-Input Low Voltage
Logic-Input Current
SDA Output Low Voltage
I2C Clock Frequency
Bus-Free Time Between START and STOP
Hold Time Repeated START Condition
SCK Low Period
SCK High Period
Setup Time Repeated START Condition
SDA Hold Time
SDA Setup Time
Setup Time for STOP Condition
Thermal Shutdown
Thermal-Shutdown Hysteresis
CONDITIONS
All LEDs off, STB = TA = +25°C
VDD
TA = +85°C
All LEDs off, STB = VDD
VIN 3.2V, VOUT = 3.9V
1x mode (VIN - VOUT) / IOUT
1.5x mode (1.5 x VIN - VOUT) / IOUT
2x mode (2 x VIN - VOUT) / IOUT
SDA = 111xxx00
SDA = 111xxx01
SDA = 111xxx10
SDA = 111xxx11
VDD = 2.7V to 5.5V
VDD = 2.7V to 5.5V
VIL = 0V or VIH =
5.5V
ISDA = 3mA
TA = +25°C
TA = +85°C
tBUF
tHD_STA
tLOW
tHIGH
tSU_STA
tHD_DAT
tSU_DAT
tSU_STO
MIN
610
VDD / 2
TYP
150
0.01
0.1
5
0.5
1.5
2.0
1
29
218
219
220
0.01
0.1
0.03
1.3
0.6
0.1
1.3
0.2
0.6
0.2
0.6
0.1
0
-0.01
100
50
0.6
0.1
+160
20
MAX
1
2.5
3.5
4.1
0.4
1
0.4
400
UNIT
mV
µA
k
mA
MHz
µs
V
V
µA
V
kHz
µs
µs
µs
µs
µs
µs
ns
µs
°C
°C
Note 1: All devices are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed
by design.
Note 2: LED current specification includes both accuracy and matching tolerance.
Note 3: Dropout voltage is defined as the M2 or F3 to GND voltage at which current into M2 or F3 drops 10% from the value at 0.2V.
All other current regulators are tested functionally by the accuracy test and guaranteed for low dropout by design.