datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2039ETPD 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2039ETPD Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
High-Linearity, 1700MHz to 2200MHz Upconversion/
Downconversion Mixer with LO Buffer/Switch
AC ELECTRICAL CHARACTERISTICS (DOWNCONVERTER OPERATION) (continued)
(MAX2039 Typical Application Circuit, VCC = +4.75V to +5.25V, TC = -40°C to +85°C, RF and LO ports are driven from 50Ω sources,
PLO = -3dBm to +3dBm, PRF = 0dBm, fRF = 1700MHz to 2200MHz, fLO = 1500MHz to 2000MHz, fIF = 200MHz, fRF > fLO, unless oth-
erwise noted. Typical values are at VCC = +5V, PRF = 0dBm, PLO = 0dBm, fRF = 1900MHz, fLO = 1700MHz, fIF = 200MHz, TC =
+25°C, unless otherwise noted.) (Notes 1, 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Noise Figure Under-Blocking
PRF = 5dBm, fRF = 2000MHz, fLO =
1810MHz, fblock = 2100MHz
(Note 5)
19
dB
LO Drive
-3
+3
dBm
2 x 2 2RF - 2LO,
73
PRF = 0dBm
Spurious Response at IF
3x3
3RF - 3LO,
PRF = 0dBm
72
LO1 to LO2 Isolation
(Note 1)
Maximum LO Leakage at RF Port
LO2 selected, 1500MHz < fLO < 1700MHz
40
52
LO1 selected, 1500MHz < fLO < 1700MHz
40
45
PLO = +3dBm
-18
Maximum LO Leakage at IF Port
PLO = +3dBm
-27.5
Minimum RF-to-IF Isolation
35
LO Switching Time
50% of LOSEL to IF settled to within 2°
50
RF Port Return Loss
18
LO Port Return Loss
LO port selected, LO and IF terminated
16
LO port unselected, LO and IF terminated
26
IF Port Return Loss
LO driven at 0dBm, RF terminated into 50Ω
20
dBc
dB
dBm
dBm
dB
ns
dB
dB
dB
_______________________________________________________________________________________ 3