datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2043ETX-T 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2043ETX-T Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
1700MHz to 3000MHz High-Linearity,
Low LO Leakage Base-Station Rx/Tx Mixer
AC ELECTRICAL CHARACTERISTICS (Downconverter Operation) (continued)
(MAX2043 Typical Application Circuit, VCC = +4.75V to +5.25V, RF and LO ports are driven from 50sources, PLO = -3dBm to
+3dBm, PRF = 0dBm, fRF = 1700MHz to 3000MHz, fLO = 1900MHz to 3000MHz, fIF = 200MHz, fRF < fLO, TC = -40°C to +85°C,
unless otherwise noted. Typical values are at VCC = +5V, PRF = 0dBm, PLO = 0dBm, fRF = 1900MHz, fLO = 2100MHz, fIF = 200MHz,
TC = +25°C, unless otherwise noted.) (Note 1)
PARAMETER
Conversion Loss Variation Over
Temperature
SYMBOL
CONDITIONS
TC = -40°C to +85°C
MIN TYP MAX UNITS
0.0075
dB/°C
Noise Figure, Single Sideband
TC = +25°C, DCS 1800:
fRF = 1710MHz to 1785MHz
NF
TC = +25°C, PCS 1900:
fRF = 1850MHz to 1910MHz
7.8
7.8
dB
TC = +25°C, UMTS 2100:
fRF = 1920MHz to 1980MHz
7.8
Noise Figure Under Blocking
Condition (Note 3)
Input Compression Point (Note 4)
IP1dB
PBLOCKER = +5dBm at 2100MHz, fRF =
2000MHz, fLO = 2190MHz,
PLO = 0dBm
High-side injection
19
dB
+23
dBm
3rd-Order Input Intercept Point
IIP3
High-side injection, fRF1 = 1900MHz,
31
fRF2 = 1901MHz, 0dBm per tone at RF port
dBm
3rd-Order Input Intercept Point
Variation
TC = -40°C to +85°C
±0.75
dB
2LO - 2RF Spur
3LO - 3RF Spur
LO Drive (Note 5)
LO1-to-LO2 Port Isolation
LO Leakage at RF Port
LO Switching Time
LO Leakage at IF Port
RF-to-IF Isolation
RF Input Return Loss
LO Input Return Loss
fRF = 1900MHz,
fLO = 2100MHz,
fSPUR = 2000MHz,
PRF = 0dBm,
PLO = 0dBm
fRF = 1900MHz,
fLO = 2100MHz,
fSPUR = 2033.333MHz,
PRF = 0dBm,
PLO = 0dBm
PLO
PLO1 = PLO2 = +3dBm,
fIF = 200MHz (Note 6)
PLO = +3dBm, fLO = 2260MHz
50% of LOSEL to IF settled within 2
degrees
PLO = +3dBm
PLO = +3dBm
LO on and IF terminated
RF and IF terminated
63
dBc
67
dBc
-3
0
+6
dBm
43
dB
-52
-38
dBm
50
ns
-35
dBm
38
dB
17
dB
14
dB
IF Return Loss
RF and LO terminated in 50, fIF = 200MHz
20
dB
(Note 7)
_______________________________________________________________________________________ 3

Share Link: 