Complete, Direct-Conversion
Tuner for DVB-S2 Applications
Table 8. PLL Register
BIT NAME BIT LOCATION (0 = LSB) DEFAULT
FUNCTION
D24
7
VCO divider setting.
1
0 = Divide by 2.
1 = Divide by 4 (default).
CPS
6
Charge-pump current mode. Users must program to 0 upon powering up the
0
device.
0 = Charge-pump current controlled by ICP bit.
1 = Charge-pump current controlled by VCO autoselect (VAS).
ICP
5
Charge-pump current. Users must program to 1 upon powering up the
0
device.
0 = 600µA typical.
1 = 1200µA typical.
X
4–0
X
Don’t care.
Table 9. VCO Register
BIT NAME BIT LOCATION (0 = LSB) DEFAULT
FUNCTION
VCO[4:0]
7–3
11001
Controls which VCO is activated when using manual VCO programming mode.
This also serves as the starting point for the VCO autoselection (VAS) mode.
VAS
2
VCO autoselection (VAS) circuit.
1
0 = Disable VCO selection must be programmed through I2C.
1 = Enable VCO selection controlled by autoselection circuit.
ADL
1
Enables or disables the VCO tuning voltage ADC latch when the VCO
0
autoselect mode (VAS) is disabled.
0 = Disables the ADC latch.
1 = Latches the ADC value.
ADE
0
Enables or disables VCO tuning voltage ADC read when the VCO autoselect
mode (VAS) is disabled.
0
0 = Disables ADC read.
1 = Enables ADC read.
Table 10. Lowpass Filter Register
BIT NAME BIT LOCATION (0 = LSB) DEFAULT
FUNCTION
LPF[7:0]
Sets the baseband lowpass filter 3dB corner frequency.
7–0
01001011 f-3dB = 4MHz + (LPF[3:0]dec - 12) x 290kHz.
Default value equates to f-3dB = 22.27MHz typical.