datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2042ETP 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2042ETP Datasheet PDF : 27 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
SiGe High-Linearity, 2000MHz to 3000MHz
Upconversion/Downconversion Mixer with LO Buffer
ABSOLUTE MAXIMUM RATINGS
VCC to GND..........................................................-0.3V to +5.5V
IF+, IF-, LOBIAS to GND.......................... -0.3V to (VCC + 0.3V)
RF, LO Input Power....................................................... +20dBm
RF, LO Current (RF and LO are DC shorted
to GND through a balun)................................................50mA
Continuous Power Dissipation (Note 1) ..............................5.0W
BJA (Notes 2, 3)............................................................ +38NC/W
BJC (Notes 1, 3)............................................................ +13NC/W
Operating Case Temperature Range
(Note 4)........................................................... -40NC to +85NC
Junction Temperature......................................................+150NC
Storage Temperature Range............................ -65NC to +150NC
Lead Temperature (soldering, 10s).................................+300NC
Note 1: Based on junction temperature TJ = TC + (BJC x VCC x ICC). This formula can be used when the temperature of the
exposed pad is known while the device is soldered down to a PCB. See the Applications Information section for details.
The junction temperature must not exceed +150NC.
Note 2: Junction temperature TJ = TA + (BJA x VCC x ICC). This formula can be used when the ambient temperature of the PCB is
known. The junction temperature must not exceed +150NC.
Note 3: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-
layer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial.
Note 4: TC is the temperature on the exposed pad of the package. TA is the ambient temperature of the device and PCB.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
+5.0V SUPPLY DC ELECTRICAL CHARACTERISTICS
(Typical Application Circuit, VCC = +4.75V to +5.25V, no input AC signals. TC = -40NC to +85NC, unless otherwise noted. Typical
values are at VCC = +5.0V, TC = +25NC, all parameters are production tested.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Supply Voltage
VCC
Supply Current
ICC
4.75 5.0 5.25
V
138 150
mA
+3.3V SUPPLY DC ELECTRICAL CHARACTERISTICS
(Typical Application Circuit, VCC = +3.0V to +3.6V, no input AC signals. TC = -40NC to +85NC, unless otherwise noted. Typical values
are at VCC = +3.3V, TC = +25NC, all parameters are production tested.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Supply Voltage
VCC
Supply Current
ICC
3.0
3.3
3.6
V
120 135
mA
RECOMMENDED AC OPERATING CONDITIONS
PARAMETER
RF Frequency Range
LO Frequency
SYMBOL
fLO
CONDITIONS
Typical Application Circuit with
C1 = 8.2pF, see Table 1 for details
(Notes 5, 6)
(Notes 5, 6)
MIN TYP MAX UNITS
2000
3000 MHz
1800
2800 MHz
IF Frequency
Using M/A-Com MABAES0029 1:1
fIF
transformer as defined in the Typical
Application Circuit, IF matching components
50
affect the IF frequency range (Notes 5, 6)
500 MHz
LO Drive
PLO (Notes 5, 6)
-3
0
+3
dBm