datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2042ETP-T 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2042ETP-T Datasheet PDF : 27 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
SiGe High-Linearity, 2000MHz to 3000MHz
Upconversion/Downconversion Mixer with LO Buffer
Typical Operating Characteristics
(Typical Application Circuit with tuning elements outlined in Table 1, VCC = +5.0V, fRF > fLO, fIF = 300MHz, PRF = 0dBm, PLO = 0dBm,
TC = +25NC, unless otherwise noted.)
+5.0V Downconverter Curves
CONVERSION LOSS vs. RF FREQUENCY
9
TC = +85NC
CONVERSION LOSS vs. RF FREQUENCY
9
CONVERSION LOSS vs. RF FREQUENCY
9
8
TC = +25NC
8
8
7
6
TC = -40NC
7
PLO = -3dBm, 0dBm, +3dBm
6
7
VCC = 4.75V, 5.0V, 5.25V
6
5
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
INPUT IP3 vs. RF FREQUENCY
40
PRF = 0dBm/TONE
TC = -40NC
35
TC = +85NC
30
TC = +25NC
5
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
INPUT IP3 vs. RF FREQUENCY
40
PRF = 0dBm/TONE
35
30
PLO = -3dBm, 0dBm, +3dBm
5
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
INPUT IP3 vs. RF FREQUENCY
40
VCC = 5.25V
PRF = 0dBm/TONE
35
VCC = 4.75V
VCC = 5.0V
30
25
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
25
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
25
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
2RF-2LO RESPONSE vs. RF FREQUENCY
75
TC = +85NC
PRF = 0dBm
70
65
TC = +25NC
60
TC = -40NC
55
50
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
2RF-2LO RESPONSE vs. RF FREQUENCY
75
PRF = 0dBm
70
PLO = +3dBm
65
60
PLO = 0dBm
55
PLO = -3dBm
50
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
2RF-2LO RESPONSE vs. RF FREQUENCY
75
PRF = 0dBm
70
65
60
55
VCC = 4.75V, 5.0V, 5.25V
50
2000 2200 2400 2600 2800 3000
RF FREQUENCY (MHz)
_______________________________________________________________________________________   7

Share Link: 