datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2044 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2044 Datasheet PDF : 39 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
SiGe, High-Linearity, 2300MHz to 4000MHz
Upconversion/Downconversion Mixer with LO Buffer
5.0V SUPPLY AC ELECTRICAL CHARACTERISTICS (DOWNCONVERTER MODE,
fRF = 3100MHz to 3900MHz, LOW-SIDE LO INJECTION) (continued)
(Typical Application Circuit with tuning elements outlined in Table 1, VCC = 4.75V to 5.25V, RF and LO ports are driven from 50I
sources, PLO = -3dBm to +3dBm, PRF = 0dBm, fRF = 3100MHz to 3900MHz, fLO = 2800MHz to 3600MHz, fIF = 300MHz, fRF > fLO,
TC = -40NC to +85NC. Typical values are at VCC = 5.0V, PRF = 0dBm, PLO = 0dBm, fRF = 3500MHz, fLO = 3200MHz, fIF = 300MHz,
TC = +25NC. All parameters are guaranteed by design, unless otherwise noted.) (Note 6)
PARAMETER
3RF - 3LO Spurious Rejection
RF Input Return Loss
LO Input Return Loss
IF Output Impedance
SYMBOL
CONDITIONS
MIN
3x3
fSPUR = fLO +
100MHz,
TC = +25NC
fSPUR = fLO +
100MHz
PRF = -10dBm
(Notes 7, 10)
82
PRF = 0dBm (Notes 7, 8) 62
PRF = -10dBm
(Notes 7, 10)
81
PRF = 0dBm (Notes 7, 8) 61
RLRF
LO on and IF terminated into a matched
impedance
RLLO
RF and IF terminated into a matched
impedance
ZIF
Nominal differential impedance at the IC’s
IF outputs
TYP
89
69
89
69
16
14
50
MAX UNITS
dBc
dB
dB
I
RF terminated into 50I, LO driven by a
IF Output Return Loss
RLIF
50I source, IF transformed to 50I using
external components shown in the Typical
16
dB
Application Circuit
RF-to-IF Isolation
LO Leakage at RF Port
2LO Leakage at RF Port
LO Leakage at IF Port
fRF = 3500MHz, PLO = +3dBm (Note 8)
33
42
fLO = 2500MHz to 4000MHz, PLO = +3dBm
(Notes 7, 8)
-31
PLO = +3dBm
-35
PLO = +3dBm (Note 8)
-28
dB
dBm
dBm
dBm
4   _______________________________________________________________________________________