µPD16661A
3. DATA BUSES
The method for lining up byte data on the data bus line is essentially the Little Endian system adopted by NEC
and Intel Corp.
3.1 16-bit data bus (BMODE = L)
Byte unit access
The address setting direction
is as shown on the right.
Word unit access
The address setting direction
is as shown on the right.
D0 to D7
00000H
00002H
00004H
:
:
D8 to D15
00001H
00003H
00005H
:
:
D0 to D7
D8 to D15
00000H
00002H
00004H
:
:
For access from the system to be performed in word units (16 bits), or byte units (8 bits), /UBE (upper-byte
enable) and A0 are used to show whether valid data is in the bytes of either (or both) D0 to D7 or D8 to D15.
/CS
/OE
/WE /UBE
A0
MODE
I/O
D0 to D7
D8 to D15
H
X
X
X
X
Not selected
Hi-z
Hi-z
L
L
H
L
L
Read
L
H
H
L
Dout
Hi-z
Dout
Dout
Dout
Hi-z
L
H
L
L
L
Write
L
H
H
L
Din
Din
X
Din
Din
X
L
H
H
X
X
Output
L
X
X
H
H
disable
Hi-z
Hi-z
Hi-z
Hi-z
Remark X : Don’t care, Hi-z : High impedance