First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
µPD4564323 for Rev. E
5. Initialization
The synchronous DRAM is initialized in the power-on sequence according to the following.
(1) To stabilize internal circuits, when power is applied, a 100 µs or longer pause must precede any signal toggling.
(2) After the pause, all banks must be precharged using the Precharge command (The Precharge all banks
command is convenient).
(3) Once the precharge is completed and the minimum tRP is satisfied, the mode register can be programmed. After
the mode register set cycle, tRSC (2 CLK minimum) pause must be satisfied as well.
(4) Two or more CBR (Auto) refresh must be performed.
Remarks 1. The sequence of Mode register programming and Refresh above may be transposed.
2. CKE and DQM must be held high until the Precharge command is issued to ensure data-bus Hi-Z.
18
Data Sheet M14376EJ2V0DS00