2.4.Lighting Specifications
2.4.1.Absolute Maximum Ratings
Parameter
Symbol
Conditions
Foward Current
IF
Note 1
Reverse Voltage
VR
-
LED Power Dissipation
PD
-
Note 1 : Refer to the foward current derating curve.
IF (mA)
120
Ta=25℃
Min. Typ. Max. Units
-
-
120
mA
-
-
8
V
-
-
0.5
W
70
0
25
50 Ta (℃)
2.4.2.Operating Characteristics
Parameter
Foward Voltage
Luminance of
Backlight Surface
Symbol
VF
L
Conditions
IF=60mA
IF=60mA
Ta=25℃
Min. Typ. Max. Units
3.8
4.1
4.4
V
35
-
-
cd/㎡
DMC16205NY-LY (AB) No.98-0065
OPTREX CORPORATION
OPTREX
Page 5/15