3. Default rate = 10.9 chars/sec + 20%
Default delay = 500 ms ± 20%
Enable (Hex F4)
- Responds with ACK.
- Clears output buffer.
- Clears last typematic key.
- Start scanning.
Default Disable (Hex F5)
- Responds with ACK.
- Resets all conditions to power-on state.
- Clears output buffer.
- Sets the default key type (scan code set 3 only).
- Set the default typematic rate/delay.
- Clears last typematic key.
- Stops scanning.
Set Default (Hex F6)
- Responds with ACK.
- Resets all conditions to power-on state.
- Clears output buffer.
- Sets the default key type (scan code set 3 only)
- Set the default typematic rate/delay.
- Clears last typematic key.
- Continues scanning.
Set All Keys (Hex F7, F8, F9, FA)
- Responds ACK.
- Clears output buffer.
- Sets all key type (affect only scan code set 3 operation).
Product Specification (V1.0) 08.07.2002