BConnector Operating Instructions, Precautions and Recommendations
Operation
Precautions
1. FPC/FFC Termination procedure.
Connector installed on the board.
1) Lift up the actuator. Use thumb or index finger.
1) Do not apply excessive force or use any type of
tool to operate the actuator.
2) Rotate down the actuator until firmly closed.
It is critical that the inserted FPC/FFC is not moved
and remains fully inserted. Should the FPC/FFC be
moved, open the actuator and repeat the process,
starting with Step 1 above.
2) The connector will assure reliable performance
when the actuator is open to 130° maximum (see
fig.1) Do not exceed this angle, as this may cause
permanent damage to the connector.
2. FPC/FFC Removal
1) Lift up the actuator.
2) Carefully remove the FPC/FFC.
3) Assure that the FPC/FFC is fully inserted parallel
to mounting surface, with the exposed conductive
traces facing down.
FPC conductor surface
(Bottom side)
40