datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX1907A 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX1907A Datasheet PDF : 43 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Quick-PWM Master Controllers for Voltage-
Positioned CPU Core Power Supplies (IMVP-IV)
ELECTRICAL CHARACTERISTICS (continued)
(Circuit of Figure 1, V+ = 15V, VCC = VDD = VSHDN = VTON = VDPSLP = VBI = VOAIN- = 5V, VFB = VCSP = VCSN = VOAIN+ = VNEG = VPOS
= 1.26V, ILIM = VCC, SUS = D5 = D1= D0= S0 = S1 = S2 = B0 = GND, VD4 = VD3 = VD2 = 1V, VB2 = 2V. TA = 0°C to +85°C, unless
otherwise specified.)
PARAMETER
On-Time (Note 1)
Minimum Off-Time (Note 1)
SYMBOL
CONDITIONS
MIN
V+ = 5V, VFB = 1.2V, TON = GND
(1000kHz)
250
tON
V+ = 12V,
VFB = 1.2V
TON = REF (550kHz)
165
TON = open (300kHz)
320
TON = VCC = (200kHz)
465
TON = GND (1000kHz)
tOFF(MIN) TON = VCC, open or REF (200kHz, 300kHz,
or 550kHz)
TYP
270
190
355
515
300
400
MAX
290
215
390
565
375
475
UNITS
ns
ns
ns
DDO Delay Time
tDDO
Measured from the time FB reaches the
voltage set by S0–S2, clock speed set by
RTIME
32
clks
SKIP Delay Time
Measured from the time when DDO is
tSKIP asserted to the time in which the controller
30
clks
begins pulse-skipping operation
BIAS AND REFERENCE
Quiescent Supply Current (VCC)
ICC
Measured at VCC, FB forced above the
regulation point
1.3
2.0
mA
Quiescent Supply Current (VDD)
IDD
Measured at VDD, FB forced above the
regulation
0.1
5
µA
Quiescent Battery Supply
Current (V+)
Shutdown Supply Current (VCC)
Shutdown Supply Current (VDD)
Shutdown Battery Supply
Current (V+)
Reference Voltage
Reference Load Regulation
FAULT PROTECTION
Output Overvoltage
Protection Threshold
IV+
VREF
ΔVREF
Measured at V+
Measured at VCC, SHDN = GND
Measured at VDD, SHDN = GND
Measured at V+, SHDN = GND,
VCC = VDD = 0 or 5V
VCC = 4.5V to 5.5V, IREF = 0
IREF = -10µA to 100µA
21
40
µA
0.1
5
µA
0.1
5
µA
0.1
5
µA
1.990 2.000 2.010
V
-10
+10
mV
Measured at FB with respect to unloaded
13
16
19
%
output voltage, DAC code = 0.7V to 1.708V
Output Overvoltage
Propagation Delay
tOVP FB forced 2% above trip threshold
10
µs
Output Undervoltage
Protection Threshold
With respect to unloaded output voltage
DAC Code = 0.7V to 1.708V
67
70
73
%
Output Undervoltage
Propagation Delay
Output Fault Blanking Time
tUVP
tBLANK
FB forced 2% below trip threshold
The clock speed is set by RTIME (Note 2)
10
µs
32
clks
_______________________________________________________________________________________ 3