datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

L5952 查看數據表(PDF) - STMicroelectronics

零件编号
产品描述 (功能)
比赛名单
L5952 Datasheet PDF : 15 Pages
First Prev 11 12 13 14 15
L5952
EXAMPLES
< Example 1 - no autoincrement mode - >
power on Vin = ON All output OFF (at RESET = “L”)
release reset RESET = “H”. Send sequence:
start I2C
Initial Set
stop I2C
1000 1000 Chip address
0000 0001 OUT3 subaddress
0000 0010 OUT3 data (8.3V, OFF)
0000 0010 OUT4 subaddress
0000 0010 OUT4 data (7.0V, OFF)
0000 0011 OUT5 subaddress
0000 0000 OUT5 data (3.3V, OFF)
start I2C
Set Turn-On
stop I2C
1000 1000 Chip address
0000 0000 OUT2 subaddress
0000 0001 OUT2 data (ON)
0000 0001 OUT3 subaddress
0000 0011 OUT3 data (8.3V, ON)
0000 0010 OUT4 subaddress
0000 0011 OUT4 data (7.0V, ON)
0000 0011 OUT5 subaddress
0000 0001 OUT5 data (3.3V, ON)
0000 0100 OUT6 subaddress
0000 0001 OUT6 data (ON)
< Example 2A - autoincrement mode - >
power on Vin = ON All output OFF (at RESET = “L”)
release reset RESET = “H”
start I2C
initial set
stop I2C
start I2C
1000 1000 Chip address
0001 0001 OUT3 subaddress, autoincrement ON
0000 0010 OUT3 data (8.3V, OFF)
0000 0010 OUT4 data (7.0V, OFF)
0000 0000 OUT5 data (3.3V, OFF)
set turn-on
stop I2C
1000 1000 Chip address
0001 0000 OUT2 subaddress, autoincrement ON
0000 0001 OUT2 data (ON)
0000 0011 OUT3 data (8.3V, ON)
0000 0011 OUT4 data (7.0V, ON)
0000 0001 OUT5 data (3.3V, ON)
0000 0001 OUT6 data (ON)
Before turning on (set turn on procedure), the output voltage should be fixed, as it is done in the initial set pro-
cedure. Do not change the bits of “turn on” and “output voltage” at the same time, otherwise the correct output
12/15

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]