datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

ACS709(2013) 查看數據表(PDF) - Allegro MicroSystems

零件编号
产品描述 (功能)
比赛名单
ACS709 Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ACS709
High Bandwidth, Fast Fault Response Current Sensor IC
In Thermally Enhanced Package
Description (continued)
the open drain Overcurrent Fault pin will transition to a logic low
state. Factory programming of the linear Hall sensor IC inside of
the ACS709 results in exceptional accuracy in both analog and
digital output signals.
The internal resistance of the copper path used for current sensing is
typically 1.1 mΩ, for low power loss. Also, the current conduction
path is electrically isolated from the low voltage device inputs and
outputs. This allows the ACS709 family of sensor ICs to be used
in applications requiring electrical isolation, without the use of
opto-isolators or other costly isolation techniques.
Applications include:
• Motor control and protection
• Load management and overcurrent detection
• Power conversion and battery monitoring / UPS systems
Selection Guide
Part Number
IP(LIN)
(A)
ACS709LLFTR-35BB-T
75
ACS709LLFTR-20BB-T
37.5
*Contact Allegro for packing options.
Sens
(Typ at VCC = 5 V)
(mV/A)
28
56
TA
(°C)
Packing*
–40 to 150 Tape and Reel, 2500 pieces per reel
Absolute Maximum Ratings
Characteristic
Supply Voltage
Filter Pin
Analog Output Pin
Overcurrent Input Pin
Overcurrent ¯F¯¯A¯U¯¯L¯¯T¯ Pin
Fault Enable (FAULT_EN) Pin
Voltage Reference Output Pin
DC Reverse Voltage: Supply Voltage, Filter, Analog
Output, Overcurrent Input, Overcurrent Fault, Fault
Enable, and Voltage Reference Output Pins
Rated Dielectric Insulation Voltage
Rated Continuous Voltage on Primary Leads
(IP+ and IP–)
Output Current Source
Output Current Sink
Operating Ambient Temperature
Junction Temperature
Storage Temperature
Symbol
VCC
VFILTER
VIOUT
VOC
V ¯F¯ ¯A¯U¯¯L¯ ¯T¯
VFAULTEN
VZCR
Notes
Rating
8
8
32
8
8
8
8
Units
V
V
V
V
V
V
V
VRdcx
–0.5
V
VISO
VWORKING
IIOUT(Source)
IIOUT(Sink)
TA
TJ(max)
Tstg
60 Hz AC, 1 minute at TA = 25°C
For single protection according to UL 1577 standard; for
higher continuous voltage ratings, please contact Allegro
Range L
2100
277
3
1
–40 to 150
165
–65 to 170
VAC
VAC
mA
mA
°C
°C
°C
Allegro MicroSystems, LLC
2
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com

Share Link: 