Data Sheet - Absolute Maximum Ratings
5 Absolute Maximum Ratings
Stresses beyond those listed in may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated in Electrical Characteristics
on page 4 is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device
reliability.
Table 2. Absolute Maximum Ratings
Parameter
Min
Max
Units
Notes
VDD, PVIN to AGND
-0.3
+7.0
V
PGND to AGND
-0.3
+0.3
V
EN, FB, NC
SW
AGND - 0.3 VDD + 0.3
V
PGND - 0.3 PVIN + 0.3 V
7.0V max
PVIN to VDD
-0.3
+0.3
V
Operating Temperature Range
-40
+85
°C
Junction Temperature (TJ-MAX)
Storage Temperature Range
Maximum Lead Temperature
(Soldering, 10 sec)
ESD Rating
+150
ºC
-65
+150
ºC
+260
ºC
Human Body Model
Operating Ratings
2
kV
HBM MIL-Std. 883E 3015.7 methods
Input Voltage Range
2.7
5.5
V
Recommended Load Current
650
mA
Junction Temperature (TJ) Range
-40
+125
ºC
In applications where high power
dissipation and/or poor package thermal
resistance is present, the maximum
ambient temperature may have to be
derated.
Maximum ambient temperature (TA-MAX)
is dependent on the maximum operating
Ambient Temperature (TA) Range
-40
+85
ºC
junction temperature (TJ-MAX-OP =
125ºC), the maximum power dissipation
of the device in the application (PD-MAX),
and the junction-to ambient thermal
resistance of the part/package in the
application (θJA), as given by the
following
equation: TA-MAX = TJ-MAX-OP – (θJA ×
PD-MAX).