DC TEST CONDITIONS
Outputs Open
Cycle = 200ns for operating current
All voltages are referenced to ground
AC TEST CONDITIONS
Output Load: 100pF + 1TTL Gate
Input Pulse Levels: 0 to 2.7V
Timing Measurement Reference Levels
Input: 1.5V
Output: 1.5V
Input pulse Rise and Fall Times: 5ns
DS1230W
ORDERING INFORMATION
PART
TEMP RANGE
SUPPLY
TOLERANCE
DS1230W-100+
0°C to +70°C
3.3V ± 0.3V
DS1230WP-100+
0°C to +70°C
3.3V ± 0.3V
DS1230W-100IND+
-40°C to +85°C
3.3V ± 0.3V
DS1230WP-100IND+ -40°C to +85°C
3.3V ± 0.3V
+Denotes a lead(Pb)-free/RoHS-compliant package.
*DS9034PC+ or DS9034PCI+ (PowerCap) required. Must be ordered separately.
PIN-PACKAGE
28 740 EDIP
34 PowerCap*
28 740 EDIP
34 PowerCap*
SPEED GRADE
(ns)
100
100
100
100
PACKAGE INFORMATION
For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. Note that a “+”,
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix
character, but the drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE PACKAGE CODE
OUTLINE NO.
LAND PATTERN NO.
28 EDIP
MDT28+3
21-0245
—
34 PCAP
PC2+4
21-0246
—
9 of 10