EVALUATION KIT
FOR SA03 PIN-OUT
FIGURE 3. FUNCTIONAL TEST CIRCUIT
EK03
The schematic of Figure 3 can be used to verify
the functionality of your amplifier and help you gain
a familiarity with proper operation. At either A Out or
B Out, with respect to ground, you should observe a
square wave approximately 30 V in amplitude with a
fixed frequency and duty cycle that varies from ap-
proximately 0 to 100% at a rate of 1 Hz. The current
limit is set to 2 amps.
����
APEX MICROTECHNOLOGY CORPORATION • TELEPHONE (520) 690-8600 • FAX (520) 888-3329 • ORDERS (520) 690-8601 • EMAIL prodlit@apexmicrotech.com