IDT723611
Commercial Temperature Range
ABSOLUTE MAXIMUM RATINGS OVER OPERATING FREE-AIR
TEMPERATURE RANGE (Unless otherwise noted)(1)
Symbol
Rating
Commercial
Unit
VCC
Supply Voltage Range
–0.5 to 7
V
VI(2)
Input Voltage Range
–0.5 to VCC+0.5
V
VO(2)
Output Voltage Range
–0.5 to VCC+0.5
V
IIK
Input Clamp Current, (VI < 0 or VI > VCC)
±20
mA
IOK
Output Clamp Current, (VO = < 0 or VO > VCC)
±50
mA
IOUT
Continuous Output Current, (VO = 0 to VCC)
±50
mA
ICC
Continuous Current Through VCC or GND
±500
mA
TSTG Storage Temperature Range
–65 to 150
°C
NOTES:
1. Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only and functional operation of
the device at these or any other conditions beyond those indicated under "Recommended Operating Conditions" is not implied. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
2. The input and output voltage ratings may be exceeded provided the input and output current ratings are observed.
RECOMMENDED OPERATING
CONDITIONS
Symbol
Parameter
Min. Max. Unit
VCC Supply Voltage
4.5 5.5 V
VIH
High-Level Input Voltage
2—V
VIL
Low-Level Input Voltage
— 0.8 V
IOH
High-Level Output Current
— –4 mA
IOL
Low-Level Output Current
— 8 mA
TA
Operating Free-Air Temperature 0 70 °C
ELECTRICAL CHARACTERISTICS OVER RECOMMENDED OPERATING
FREE-AIR TEMPERATURE RANGE (Unless otherwise noted)
IDT723611
Commercial
tA = 15, 20, 30 ns
Parameter
Test Conditions
Min. Typ. (1) Max. Unit
VOH
VCC = 4.5V,
IOH = –4 mA
2.4
V
VOL
VCC = 4.5V,
IOL = 8 mA
0.5
V
ILI
VCC = 5.5V,
VI = VCC or 0
— ±50 µA
ILO
VCC = 5.5V,
VO = VCC or 0
— ±50 µA
ICC(2)
VCC = 5.5V,
IO = 0 mA,
VI = VCC or GND
Outputs HIGH
60
mA
Outputs LOW
— 130
Outputs Disabled
60
CIN
VI = 0,
f = 1 MHz
4
pF
COUT
VO = 0,
f = 1 MHZ
8
pF
NOTES:
1. All typical values are at VCC = 5V, TA = 25°C.
2. For additional ICC information, see the following page.