IDTCV109E
CLOCK GENERATOR FOR DESKTOP PC PLATFORMS
COMMERCIAL TEMPERATURE RANGE
ELECTRICAL CHARACTERISTICS - CPU AND SRC 0.7 CURRENT MODE
DIFFERENTIAL PAIR(1)
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = 0°C to +70°C, Supply Voltage: VDD = 3.3V ± 5%; CL = 2pF
Symbol
ZO
VOVS
VUDS
VHIGH
VLOW
VOVS
VUDS
VCROSS(ABS)
d - VCROSS
ppm
TPERIOD
Parameter
Test Conditions
Current Source Output Impedance(2) VO = VX
Maximum Voltage (Overshoot)
Minimum Voltage (Undershoot)
Voltage HIGH(2)
Voltage LOW(2)
Max Voltage(2)
Statistical measurement on single-ended signal using
oscilloscope math function
Measurement on single-ended signal using absolute value
Min Voltage(2)
Crossing Voltage (abs)(2)
Crossing Voltage (var)(2)
Variation of crossing over all edges
Long Accuracy(2,3)
See TPERIOD Min. - Max. values
400MHz nominal, no Intel spec
333.33MHz nominal, no Intel spec
266.66MHz nominal, no Intel spec
Average Period(3)
200MHz nominal
Min.
Typ.
Max.
Unit
3000
—
—
Ω
—
—
VH + 0.3
V
-0.3
—
—
V
660
—
850
mV
–150
—
150
—
—
1150
mV
–300
—
—
250
—
550
mV
—
—
140
mV
–300
—
300
ppm
2.4993
—
2.9991
—
3.7489
—
2.5008
3.0009
3.7511
4.9985
—
5.0015
ns
TPERIOD Average Period(3)
166.66MHz nominal
133.33MHz nominal
100MHz nominal
400MHz spread, no Intel spec
333.33MHz spread, no Intel spec
266.66MHz spread, no Intel spec
200MHz spread
5.9982
—
6.0018
7.4978
—
9.997
—
2.4993
—
2.9991
—
3.7489
—
7.5023
10.003
2.5008
3.0009
3.7511
4.9985
—
5.0266
ns
166.66MHz spread
5.9982
—
6.032
133.33MHz spread
7.4978
—
7.54
100MHz spread
9.997
—
10.0533
tR
Rise Time(2)
VOL = 0.175V, VOH = 0.525V
175
—
700
ps
tF
Fall Time(2)
VOL = 0.175V, VOH = 0.525V
175
—
700
ps
d-tR
Rise Time Variation(2)
—
—
125
ps
d-tF
Fall Time Variation(2)
—
—
125
ps
dT3
Duty Cycle(2)
Measurement from differential waveform
45
—
55
%
tSK3
Skew(2)
VT = 50%
—
—
100
ps
tJCYC-CYC Jitter, Cycle to Cycle(2)
Measurement from differential waveform
—
—
85
ps
NOTES:
1. SRC clock outputs run only at 100MHz or 200MHz. Specs for 133.33 and 166.66 do not apply to SRC clock pair.
2. This parameter is guaranteed by design, but not 100% production tested.
3. All long term accuracy and clock period specifications are guaranteed with the assumption that the REF output is at 14.31818MHz.
16