U
OPERATIO
SINGLE CELL +
Li-Ion BATTERY
BAT
OUT
LTC4063
FB
GND
VOUT
R2
COUT
R1
4063 F01
Figure 1. Adjustable Linear Regulator
Figure 1 shows how an external resistor divider sets the
regulator output voltage. The output voltage can be set
LTC4063
anywhere between 1.2V and 4.2V, although the upper limit
is limited by the battery voltage minus the regulator
dropout voltage.
VOUT = 800mV • ⎛⎝⎜1+ RR21⎞⎠⎟
In order to maintain stability under light load conditions,
the maximum recommended value of R1 is 160k.
APPLICATIO S I FOR ATIO
Programming Charge Termination
The LTC4063 terminates a charge cycle using several
methods, allowing the designer considerable flexibility in
choosing an ideal charge termination algorithm. Table 1
shows a brief description of the different termination
methods and their behavior.
Charge Time Termination
Connecting a capacitor (CTIMER) to the TIMER pin enables
the timer and selects Charge Time Termination. The total
charge time is set by:
Time(Hours) = 0.1µF • 3 Hours
CTIMER
When the programmed time has elapsed, the charge cycle
terminates and the charger enters standby mode. Subse-
quent recharge cycles terminate when half the programmed
time has elapsed.
The IDET pin determines the behavior of the CHRG output.
Connecting a resistor (RDET) from the IDET pin to ground
sets the charge current detection threshold, IDETECT:
IDETECT
=
RPROG
10RDET
• ICHG
=
100V
RDET
or
RDET
=
100V
IDETECT
Table 1
METHOD
Charge Time
Termination
TIMER
0.1µF to
GND
IDET
RDET to
GND
CHARGER DESCRIPTION
Charges for 3 Hours. After 3 Hours, the Charger
Stops Charging and Enters Standby Mode.
Recharge Cycles Last for 1.5 Hours
CHRG OUTPUT DESCRIPTION
Pull-Down State While IBAT > IDETECT. High Impedance
State While IBAT < IDETECT or When Charging is Stopped
0.1µF to NC Charges for 3 Hours. After 3 Hours, the Charger Pull-Down State When Charging. High Impedance State
GND
Stops Charging and Enters Standby Mode.
When Charging is Stopped
Recharge Cycles Last for 1.5 Hours
Charge Current
Termination
GND RDET to Charges Until Charge Current Drops Below
GND IDETECT, Then Enters Standby Mode
Pull-Down State When Charging. High Impedance State
When Charging is Stopped
GND
NC Charges Indefinitely Until CHGEN Pin is Pulled Pull-Down State When Charging. High Impedance State
High
When Charging is Stopped
User-Selectable VCC RDET to Charges Indefinitely Until CHGEN Pin is Pulled Pull-Down State While IBAT > IDETECT. High Impedance
Charge
GND High. SmartStart is Disabled
State While IBAT < IDETECT or When Charging is Stopped
Termination
VCC
NC Charges Indefinitely Until CHGEN Pin is Pulled Pull-Down State When Charging. High Impedance State
High. SmartStart is Disabled
When Charging is Stopped