APPLICATION NOTES
POWER SUPPLIES
The output voltage of the DHD2805S may be adjusted from
90% to 110% of nominal value by the use of a 50Kpotenti-
ometer as shown. Adjustment beyond this range is possible
however certain characteristics of the converter such as but
not limited to input voltage range, efficiency, ripple and tem-
perature performance will change. Characterization by the user
is recommended in such applications.
LOAD FAULT RESPONSE
Load fault conditions include short-circuit and severe over-
load conditions. The DHD2805S converter responds to load
faults by turning off all power conversion circuits for 250mS
and then attempting to restart for 10mS (typical). The net "on"
duty factor during a fault is very low resulting in low converter
dissipation and immunity from overheating at 125°C. Current
beyond rated can flow into the load at startup time. This al-
lows the converter to bring up capacitive and other difficult
load types more reliably than competing converters.
Adjust/comp (pin 3) may be driven by external circuitry refer-
enced to pin 2 (-output) if desired. Grounding pin 3 causes
voltage to increase (25% typically) while driving pin 3 above
1.3V causes output voltage to decrease. Pin 3 may be driven
through 10Kor more if connection of the comp function is
also required.
The comp function of pin 3 allows capacitive loads as large
as 1000µF to be accommodated on the DHD2805S without
loss of stability. This feature may be utilized by connecting a
10nF capacitor between pins 3 and 1. This is generally recom-
mended when low ESR load capacitances of 100µF or greater
are used.
SHUTDOWN PLUS
Pin 5 is used for remote shutdown, output fault detection,
and/or setting the input voltage point at which the converter
will turn on as shown in the typical application diagram. No
connection to pin 5 is necessary for normal operation of the
converter. Pin 5 is referenced to the -input (pin 7).
Shutdown may be implemented by simply connecting pin 5
to an open collector logic output or switch rated at 2.5mA,
25Vdc or higher.
Input voltage turn on point is programmed with a single resis-
tor from pin 5 to 7. An input turn on/off hysteresis (typically
3.5% of Vin) will be observed. This should be considered when
making or verifying set point adjustment. The value of the
setpoint resistor may be determined by the following:
R= 210·10³ (±10% accuracy at 25°C)
ETO-9.5
Set point temperature coefficient is typically +400ppm/°C.
Output fault monitoring is accomplished by observing pin 5
with a high impedance monitoring circuit. Pin 5 voltage drops
from over 10V to below 1V when a load fault causes the con-
verters fault protection circuitry to activate. It will remain low
for at least 100mS and return high. If the load fault is still
present pin 5 will return low and the cycle will repeat. A resis-
tor >400Kfrom pin 5 to 7 provides pull down for pin 5 if
there is no input setpoint programming resistor already in place.
4
Rev. C 3/05