RoHS
Compliant
2 Way 0º Power Divider
5-2400MHz
Electrical Specifications: TA = 25°C, Z0 = 75 1
Parameter
Insertion Loss
Test
Conditions
-
Amplitude Unbalance (Nominal
-
0dB)
Phase Unbalance (Nominal 180º)
-
Return Loss: Input
-
Return Loss: Output
-
Isolation (between outputs)
-
Frequency
5 - 870 MHz
870 - 1000 MHz
1000 - 2150 MHz
2150 - 2400 MHz
5 - 1000 MHz
1000 - 2150 MHz
2150 - 2400 MHz
5 - 1000 MHz
1000 - 2150 MHz
2150 - 2400 MHz
5 - 2150 MHz
2150 - 2400 MHz
5 - 1000 MHz
1000 - 2400 MHz
5 - 2400 MHz
Units
dB
dB
dB
dB
dB
dB
dB
º
º
º
dB
dB
dB
dB
dB
Min
-
-
-
-
-
-
-
-
-
-
9
6
10
6
10
MAPDCT0026
V1
Typ
0.7
0.9
1.2
2.8
0.2
0.8
1.3
2
2
4
10
9
15
9
18
Max
1.0
1.1
2.5
3.9
± 0.7
± 1.5
± 1.8
±5
± 10
± 12
-
-
-
-
-
Absolute Maximum Ratings 1,2
Parameter
Max Input Power
DC current
Operating Temperature
Storage Temperature
Absolute Maximum
1W
240mA
-40°C to +80°C
-40°C to +85°C
Recommended PCB Configuration
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
• India Tel: +91.80.4155721
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.