Electrical Specifications: TA = 25°C, Z0 = 50 Ω 3
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss 4
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
dB
—
0.65
0.85
dB
—
0.80
1.00
dB
—
1.00
—
Isolation
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
dB
27
29.0
—
dB
21
23.0
—
dB
—
18.5
—
Return Loss
DC – 3 GHz
dB
—
20
—
IP3
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
—
57
—
IP2
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
—
81
—
P.1dB
2nd Harmonic
3rd Harmonic
VC = 0 V / 2.5 V
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
dBm
—
dBc
—
dBc
—
38
—
-80
-71
-68
-65
Trise, Tfall
10% RF to 90% RF, 90% to 10% RF, VC = 0 V / 2.5 V
µS
—
0.2
—
Ton, Toff
50% control to 90% RF, 50% control to 10% RF, VC = 0 V / 2.5 V
µS
—
0.2
—
Transients
mV
—
35
—
Control Current
VC = 0 V / 2.5 V, 34 dBm
µA
—
10
50
3. External DC blocking capacitors are required on all RF ports.
4. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 500 MHz, 39 pF for 0.5 - 3 GHz.
Absolute Maximum Ratings 5,6
Parameter
Input Power
(0.5 - 3.0 GHz, 2.5 V Control)
Voltage
Operating Temperature
Absolute Maximum
+38 dBm
± 8.5 volts
-40°C to +85°C
Storage Temperature
-65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table 7,8
V1 V2
V3
V4
ANT- ANT- ANT- ANT-
RF1 RF2 RF3 RF4
1
0
0
0
On
Off
Off
Off
0
1
0
0
Off
On
Off
Off
0
0
1
0
Off
Off
On
Off
0
0
0
1
Off
Off
Off
On
7. Differential voltage, V (state 1) -V (state 2), must be 2.5 V
minimum.
8. 0 = -5 V to +2.5 V, 1 = -2.5 V to +5 V
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.