datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX1773AEUP(2017) 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX1773AEUP
(Rev.:2017)
MaximIC
Maxim Integrated MaximIC
MAX1773AEUP Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MAX1773/MAX1773A
Power Source Selector for
Dual-Battery Systems
Electrical Characteristics (continued)
(VBATA = VBATB = 16.8V, CVDD = 3.3μF, VMINV = 0.93V, VEXTLD = VACDET = 28V, VTCOMP = 3V, VTHMA = VTHMB = 1.65V,
VBATSEL = 0V, CCOMA = CCOMB = CDISA = CDISB = CCHGA = CCHGB = CPDS = 5nF, TA = -40°C to +85°C, unless otherwise noted.)
PARAMETER
STATUS OUTPUTS
ACPRES Sink Current
BATSTAT Sink Current
ACPRES Leakage Current
BATSTAT Leakage Current
TRANSITION TIMES
Battery Switchover Delay
Battery Action Delay
Thermistor Action Delay
AC to Battery Switchover Delay
Battery to AC Switchover Delay
CHG_ Turn-On Delay
CONDITIONS
VACPRES = 0.4V
VACPRES = 5.5V
VBATSTAT = 0.4V
VBATSTAT = 5.5V
VACPRES = 5.5V
VBATSTAT = 5.5V
VACDET = 2.2V, VMINV = 0.93V (Note 6)
VACDET = 2.2V, VMINV = 0.93V (Note 7)
VACDET = 2.2V, VMINV = 0.93V (Note 8)
VACDET = 2.2V, VMINV = 0.93V (Note 9)
VACDET = 2.2V, VMINV = 0.93V (Note 10)
(Note 11)
MIN TYP MAX UNITS
1
mA
30
1
mA
30
1
µA
1
µA
5
µs
260
µs
12
µs
10
µs
260
µs
130
530
µs
Note 2: TCOMP undervoltage lockout sets the MAX1773/MAX1773A’s internal status bits for the batteries to be designated as
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
“absent” (VTHM_ > VTCOMP).
VACDET must remain above 2.2V, except in power-up.
COMA cannot sink current until VCOMB > VBATB - 2V. Likewise, COMB cannot sink current until VCOMA > VBATA - 2V.
DISA cannot sink current until VDISB > VEXTLD - 2V. Likewise, DISB cannot sink current until VDISA > VEXTLD - 2V.
Battery Switchover Delay starts when either VCOM_ or VDIS_ of the connected battery begins to rise and ends when
both VCOM_ and VDIS_ of the other battery have fallen 3V below their sources (Figure 1 and 2).
Battery Action Delay starts when the connected battery’s voltage falls below 5 x VMINV and ends when both VCOM_ and
VDIS_ of the other battery have fallen 3V below their sources (Figure 1 and 2).
Thermistor Action Delay begins when VTHM_ of the connected battery rises above VTCOMP and ends when both VCOM_
and VDIS_ of the other battery have fallen 3V below their sources (Figure 3 and 4).
AC to Battery Switchover Delay begins when VACDET falls below its threshold and ends when both VCOM_ and VDIS_ of
the battery being switched to have fallen 3V below their sources (Figure 5).
Note 10: Battery to AC Switchover Delay begins when VACDET rises above its threshold and ends when VDIS_ of the battery being
switched from has begun to rise (Figure 6).
Note 11: CHG_ Turn-on Delay begins when VCHG_ of the battery being switched from begins to rise and ends when VCHG_ of the
battery being switched to begins to fall (Figure 7 and 8).
www.maximintegrated.com
Maxim Integrated 7

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]