High-Linearity, 650MHz to 1000MHz Upconversion/
Downconversion Mixer with LO Buffer/Switch
AC ELECTRICAL CHARACTERISTICS (700MHz BAND DOWNCONVERTER OPERATION)
(Typical Application Circuit, optimized for the 700MHz band (see Table 1), C1 = 7pF, C5 = 3.3pF, L1 and C4 are not used, VCC =
4.75V to 5.25V, RF and LO ports driven from 50Ω sources, PLO = -3dBm to +3dBm, PRF = 0dBm, fRF = 650MHz to 850MHz, fLO =
790MHz to 990MHz, fIF = 140MHz, fLO > fRF, TC = +25°C, unless otherwise noted. Typical values are at VCC = 5V, PRF = 0dBm,
PLO = 0dBm, fRF = 750MHz, fLO = 890MHz, fIF = 140MHz, TC = +25°C, unless otherwise noted.) (Notes 8, 10)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Conversion Loss
Input 1dB Compression Point
LC
P1dB
fRF = 750MHz, PRF = 0dBm, PLO = 0dBm
6.1
6.9
8.1
dB
27.7
dBm
Input Third-Order Intercept Point
fRF1 = 749MHz, fRF2 = 750MHz,
IIP3
fLO = 890MHz, PRF = 0dBm/tone,
PLO = 0dBm
32
37
dBm
LO Leakage at IF Port
LO Leakage at RF Port
RF-to-IF Isolation
PLO = +3dBm
PLO = +3dBm
-33
-21
dBm
-20
-13
dBm
36
49
dB
2LO-2RF Spurious Response
2x2
40
72
dBc
3LO-3RF Spurious Response
3x3
65
82
dBc
AC ELECTRICAL CHARACTERISTICS (UPCONVERTER OPERATION)
(Typical Application Circuit, L1 = 4.7nH, C4 = 6pF, C1 = 82pF, C5 not used, VCC = 4.75V to 5.25V, RF and LO ports are driven from
50Ω sources, PLO = -3dBm to +3dBm, PIF = 0dBm, fRF = 815MHz to 1000MHz, fLO = 960MHz to 1180MHz, fIF = 160MHz, fLO > fRF,
TC = -40°C to +85°C, unless otherwise noted. Typical values are at VCC = 5V, PIF = 0dBm, PLO = 0dBm, fRF = 910MHz, fLO =
1070MHz, fIF = 160MHz, TC = +25°C, unless otherwise noted.) (Note 8)
PARAMETER
Conversion Loss
Conversion Loss Flatness
Conversion Loss Variation Over
Temperature
Input Compression Point
Input Third-Order Intercept Point
Input IP3 Variation Over
Temperature
LO ± 2IF Spur
LO ± 3IF Spur
Output Noise Floor
SYMBOL
CONDITIONS
Lc
Flatness over any one of three frequency
bands (fIF = 160MHz):
fRF = 827MHz to 849MHz
fRF = 869MHz to 894MHz
fRF = 880MHz to 915MHz
TC = +25°C to -40°C
TC = +25°C to +85°C
P1dB
IIP3
IIP3
(Note 9)
fIF1 = 160MHz, fIF2 = 161MHz,
PIF = 0dBm/tone, fLO = 1070MHz,
PLO = 0dBm, TC = +25°C (Note 10)
TC = +25°C to -40°C
TC = +25°C to +85°C
POUT = 0dBm (Note 11)
MIN TYP MAX UNITS
7.4
dB
±0.3
dB
-0.3
0.4
27
32
36
1.2
-0.9
64
83
-167
dB
dBm
dBm
dB
dBc
dBc
dBm/Hz
Note 6: Operation outside this range is possible, but with degraded performance of some parameters.
Note 7: Not production tested.
Note 8: All limits include external component losses. Output measurements are taken at IF or RF port of the Typical Application Circuit.
Note 9: Compression point characterized. It is advisable not to continuously operate the mixer RF/IF inputs above +12dBm.
Note 10: Guaranteed by design.
Note 11: Measured with external LO source noise filtered, so its noise floor is -174dBm/Hz. This specification reflects the effects of all
SNR degradations in the mixer, including the LO noise as defined in Application Note 2021: Specifications and Measurements
of Local Oscilator Noise in Integrated Circuit Base Station Mixers.