1300MHz to 2700MHz Variable-Gain
Amplifier with Analog Gain Control
ABSOLUTE MAXIMUM RATINGS
VCC to GND ...........................................................-0.3V to +5.5V
VCNTL to GND (with VCC applied) .............................0V to 4.75V
Current into VCNTL pin (VCC grounded) .............................40mA
All Other Pins to GND.................................-0.3V to (VCC + 0.3V)
RF Input Power (IN, IN_A, ATTN_OUT, OUT_A) ...........+20dBm
RF Input Power (AMP_IN)...............................................+12dBm
θJA (natural convection)...................................................35°C/W
θJA (1m/s airflow) .............................................................31°C/W
θJA (2.5m/s airflow) ..........................................................29°C/W
θJC (junction to exposed pad) .........................................10°C/W
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Junction Temperature ......................................................+150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
(VCC = +4.75V to +5.25V, no RF signals applied, all input and output ports terminated with 50, TA = -40°C to +85°C, unless other-
wise noted. Typical values are at VCC = +5.0V, TA = +25°C, unless otherwise noted.)
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
Supply Voltage
4.75
5
5.25
V
Supply Current
R1 = 1.2k, R2 = 2k (Note 1)
180 230
mA
RSET1 Current
RSET2 Current
Gain-Control Voltage Range
R1 = 1.2k (Note 1)
R1 = 2k (Note 1)
(Note 2)
1
mA
0.6
mA
1.0
4.5
V
Gain-Control Pin Input Resistance VCNTL = 1V to 4.5V
50
k
RECOMMENDED AC OPERATING CONDITIONS
PARAMETER
Frequency Range
(Note 3)
CONDITIONS
MIN
1300
TYP
MAX UNITS
2700 MHz
AC ELECTRICAL CHARACTERISTICS
(Typical Operating Circuit with one attenuator connected, VCC = +4.75V to +5.25V, TA = -40°C to +85°C, fIN = 1700MHz to
2500MHz, unless otherwise noted. Typical values are at VCC = +5.0V, R1 = 1.2k, R2 = 2k, POUT = +5dBm, fIN = 2100MHz,
VCNTL = 1V, 50system impedance, second attenuator is not connected, TA = +25°C, unless otherwise noted.) (Note 4)
PARAMETER
Gain
Maximum Gain Variation
CONDITIONS
TA = +25°C, VCC = 5.0V, fIN = 2100MHz
TA = +25°C, VCC = 5.0V, fIN = 1560MHz
TA = +25°C, VCC = 5.0V, fIN = 1500MHz
TA = +25°C, VCC = 5.0V, fIN = 1450MHz
VCNTL = 1V
TA = +25°C to -40°C
VCNTL = 1.8V
VCNTL = 2.6V
VCNTL = 3.5V
VCNTL = 1V
TA = +25°C to +85°C
VCNTL = 1.8V
VCNTL = 2.6V
VCNTL = 3.5V
MIN
13.5
11.5
11.5
11.5
TYP
15.5
14.5
14.3
14
+0.9
+0.41
+0.09
-0.16
-1
-0.56
-0.32
+0.1
MAX
17.5
16.5
16.5
16.5
UNITS
dB
dB
2 _______________________________________________________________________________________