datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX8822 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX8822 Datasheet PDF : 15 Pages
First Prev 11 12 13 14 15
Ultra-Efficient Negative Charge-Pump LED
Driver with Dual LDOs in 3mm x 3mm Thin QFN
Table 1. ENLED Pulse Count and Programmed LED_ Current
ENLED PULSE
COUNT*
PROGRAMMED LED_ CURRENT
(mA)
ENLED PULSE COUNT*
PROGRAMMED LED_ CURRENT
(mA)
1
24.0
17
2.8
2
22.4
18
2.4
3
20.8
19
2.0
4
19.2
20
1.6
5
17.6
21
1.4
6
16.0
22
1.2
7
14.4
23
1.0
8
12.8
24
0.8
9
11.2
25
0.7
10
9.6
26
0.6
11
8.0
27
0.5
12
6.4
28
0.4
13
5.6
29
0.3
14
4.8
30
0.2
15
4.0
31**
0.1
16
3.2
*Rising edge.
**If ENLED is pulsed more than 31 times, the pulse count restarts at 1 on the 32nd rising edge.
Low LED Current Levels
The MAX8822 internally generates a PWM signal to
obtain higher resolution at lower currents. As LED cur-
rent is set below 6.4mA, the IC adjusts not only LED DC
current, but the duty cycle is controlled by the PWM
signal. The frequency of the PWM dimming signal is set
at 1kHz with a minimum duty cycle of 1/16 to avoid the
LED flickering effect to human eyes. Table 2 shows the
current level and the corresponding duty cycle.
LDO1/LDO2 Output Voltage Control
Similar to the LED dimming control structure, the
MAX8822 uses serial-pulse control to program the out-
put voltages of LDO1 and LDO2 to one of sixteen differ-
ent combinations. To program the LDO voltages, pulse
ENLDO low (500ns to 500µs pulse width), as shown in
Figure 2. An internal register accumulates the pulse
count on the rising edge of the ENLDO pulse. An initial
pulse (tINIT) is required to enable the LDOs from shut-
down. See Table 3 for LDO voltage combinations and
the corresponding ENLDO pulse count. When the
desired pulse count is met, hold ENLDO high for at
least 2.5ms (tHOLD) to internally latch the pulse-count
value and program the LDO output voltages at the
desired level. If ENLDO is pulsed for more than 15
counts, LDO1 and LDO2 are off when the count is
Table 2. Internal PWM Duty Cycle vs. LED
Set Current
DUTY CYCLE
(n/16th)
16
14
12
10
16
14
12
10
16
14
ILED (mA)
6.4
5.6
4.8
4.0
3.2
2.8
2.4
2.0
1.6
1.4
DUTY CYCLE
(n/16th)
12
10
8
7
6
5
4
3
2
1
ILED (mA)
1.2
1.0
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
latched (the count does not roll over). To program new
LDO_ output voltages, follow the previous sequence
from the beginning. Do not include the initial tINIT pulse
when programming LDO voltages unless enabling the
LDOs from shutdown (the OFF setting is not shutdown).
Pulling ENLDO low for greater than 2.5ms places the
LDOs in shutdown.
______________________________________________________________________________________ 11