MB39A123
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Conditions
Value
Unit
Min
Typ
Max
Start power supply voltage
VCC
ch.5, ch.6, VCC, VCCO
terminals
1.7
11
V
Power supply voltage
Reference voltage output current
Input voltage
VCC VCC, VCCO terminals
IREF VREF terminal
INE1 to INE6 terminals
VINE INA terminal
INS terminal
VDTC DTC2 to DTC6 terminals
2.5
1
0
0.2
0
0
4
11
V
0
mA
VCC 0.9 V
VCC 1.8 V
VREF
V
VREF
V
Control input voltage
VCTL
CTL, CTL1 to CTL6
terminals
0
11
V
Output current
IO
OUT1-1, OUT1-2, OUT2 to
OUT6 terminals
15
+15 mA
OUT1-1, OUT1-2, OUT2 to
Total gate charge of external FET
Qg
OUT6 terminals
connection FET
fosc = 2 MHz
2.6
7.5 nC
Oscillation frequency
Timing capacitor
Timing resistor
Soft-start capacitor
Short-circuit detection capacitor
fOSC
CT
RT
CS
CSCP
CS1 to CS6 terminals
0.2
1.0
2.0 MHz
27
100
680 pF
3.0
6.8
39
k
0.1
1.0
µF
0.1
1.0
µF
Reference voltage output
capacitor
CREF
0.1
1.0
µF
Operating ambient temperature
Ta
30
+25
+85
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
8

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]