![](/html/Fujitsu/481834/page52.png)
MB86616
5-26 Reset Condition Generation
Parameter
Symbol Pin name
Values
Unit
Min.
Max.
Write “1” to RST OUT bit→
RST↓
ts261
RST
10
ns
RST↓→SCSI bus clear
ts262
All SCSI bus
pins
10
ns
Write “0” to RST OUT bit→
RST↑
ts263
RST
10
ns
Write
strobe
RST
SCSI bus
signals
other than
RST
tS261
tS262
52