datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MT9075B 查看數據表(PDF) - Mitel Networks

零件编号
产品描述 (功能)
比赛名单
MT9075B
Mitel
Mitel Networks Mitel
MT9075B Datasheet PDF : 82 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Preliminary Information
MT9075B
Tx
0.68uF RT
1:2
TTIP
TRING
RT
MT9075B
RTIP
RRING
1:1
120Ω/
75Ω
Rx
Figure 4 - Analog Line Interface
The template for the transmitted pulse, as specified in
G703, is shown in Figure 5. The nominal peak voltage
of a mark is 3 volts for 120 twisted pair applications
and 2.37 volts for 75 coax applications. The ratio of
the amplitude of the transmit pulses generated by TTP
and TRING is between 0.95 and 1.05.
Percentage of
Nominal Peak
120
110
100
90
80
269nS
244nS
194nS
Manufacturer
For Tx
For Rx
Filtran
5721-1
5721-2
Pulse Engineering PE-65351 PE-64934
Midcom
50027
50026
OSEC
02934/A
02935/A
Table 1 - Transformer Manufacturers and Part
Numbers
Timing Source
The MT9075B can use either a clock or crystal,
connecting to pins OSC1 and OSC2, as the
reference timing source.
Figure 6 shows a 20MHz clock oscillator, with 50ppm
tolerance, directly connected to the OSC1 pin of the
MT9075B.
+5V
MT9075B
OSC1
20MHz
OUT
Vdd
GND
.1µF
OSC2
(open)
50
10
0
-10
Nominal Pulse
-20
219nS
488nS
Figure 5 - Pulse Template (G.703)
Transformer Recommendation
Figure 6 - Clock Oscillator Circuit
Alternatively, a crystal oscillator may be used. A
complete oscillator circuit made up of a crystal,
resistors and capacitors is shown in Figure 7. The
crystal specification is as follows.
Frequency:
Tolerance:
Oscillation Mode:
Resonance Mode:
Load Capacitance:
Maximum Series Resistance:
Approximate Drive Level:
20MHz
50ppm
Fundamental
Parallel
32pF
35
1mW
Table 1 shows a list of recommended transformers
for the MT9075B line interface.
9