datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

NJM2390U 查看數據表(PDF) - Japan Radio Corporation

零件编号
产品描述 (功能)
比赛名单
NJM2390U
JRC
Japan Radio Corporation  JRC
NJM2390U Datasheet PDF : 4 Pages
1 2 3 4
NJM2380/A, NJM2390/A
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Cathode Voltage
VKA
Continuous Cathode Current
IKA
Reference Input Current
IREF
Power Dissipation
PD
Operating Temperature Range
TOPR
Storage Temperature Range
TSTG
RATINGS
+20
-100 to 150
-0.05 to 10
(DIP8)
700
(DMP8)
300
(EMP8)
300
(SOT89)
350
(SOT23[MTP5])
200
-40 to +85
-50 to +150
(Ta=25°C)
UNIT
V
mA
mA
mW
°C
°C
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
Cathode Voltage
Cathode Current
VKA
VREF
-
18
V
IK
1
100
mA
ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
Reference Voltage
VREF
Reference Voltage
Change vs. Cathode
Voltage Change
Reference Input Current
Minimum Input Current
Cathode Current (Off Cond.)
Dynamic Impedance
VREF/VKA
IREF
IMIN
IOFF
ZKA
CONDITIONS
VKA=VREF(*1)
VKA=VREF(*1), A Version
VREF│≤VKA10V(*2)
10VKA18V(*2)
R=10k, R2=(*2)
VKA=VREF(*1)
VKA=18V, VREF=0V(*3)
VKA=VREF, f1kHz
1mAIK100mA(*1)
MIN.
2415
2440
-
-
-
-
-
-
(IK=10mA, Ta=25°C)
TYP. MAX. UNIT
2465 2515 mV
2465 2490
±1.4 ±2.7 mV/V
±1
±2 mV/V
2
4
µA
0.4
1.0
mA
0.1
1.0
µA
0.2
-
TEMPERATURE CHARACTERISTICS
(IK=10mA, Ta=-20 to +85°C)
PARAMETER
SYMBOL
CONDITIONS
MIN. TYP. MAX. UNIT
Reference Voltage Change
Reference Input Current Change
VREF
IREF
VKA=VREF(*1)
R1=10k, R2=(*2)
-
8
17
mV
-
0.4
1.2
µA
The "Reference Voltage Change" and "Reference Input Current Change" is tested to using some samples of the first five lots. These
"TEMPERATURE CHARACTERISTICS" are not guaranteed.
VREF…Reference voltage includes error.
(*1) : TEST CIRCUIT 1 (Fig.1)
(*2) : TEST CIRCUIT 2 (Fig.2)
(*3) : TEST CIRCUIT 3 (Fig.3)
-2-
Ver.2007-02-07