NJU3552
s TERMINAL DESCRIPTION IN OTP PROGRAMMING MODE
No.
SYMBOL INPUT/OUTPUT
FUNCTION
13
2 - 4,
7,
15 - 17,
21
22,
23
11
10
9
24
12
RESET
INPUT
RESET terminal.
When the low-level input-signal, the system is initialized.
D0 - D7 INPUT/OUTPUT Data bus
CNT1
CNT2
REQ
CLK
PROM
VDD
VSS
INPUT
INPUT
OUTPUT
INPUT
INPUT
-
-
OTP control input terminal
Request output terminal
Clock input terminal
OTP programming enable terminal
Power Source (5V)
Power Source (0V)
Note 1) Use at VDD=5V in OTP programming mode.
2) Non connect anything to the other terminals.
s Difference between NJU3552 (OTP version) and NJU3502 (MASK version)
q Operating mode
NJU3552 has two operating modes. One is ”Normal operating mode” and the other is “OTP programming
mode”.
Normal operating mode
The ”TEST” terminal is set to low level. (The terminal is recommended to connect to GND.)
Operating voltage range; 2.7V ~ 5.5V.
OTP Programming mode
User program is read out from or written into the OTP by the universal programmer “SUPERPRO/L” and
converting adapter made by XELTEK co,.(USA).
q Option information set in the initialization
When the initialization is performed(RESET terminal is “L”), the operation information stored in option area is
set as shown in the following timing chart . The option information is set in the term of 1 / fOSC x 256clock after
RESET releasing and oscillation stability time. After information set, the program counter is set to 0000H and
the NJU3552 operates in normal.
[ TIMING CHART ]
Oscillation
Stability
Time
Option information setting
1/fOSCx256clock
Normal
Operation
Oscillator
Clock
Oscillation
Start
PC=0000H
RESET
fOSC=4MHz
about 64µsec
-3-