RE46C160
CMOS Alarm ASIC
Preliminary Product Specification
R&E International
DEVICE DESCRIPTION and APPLICATION NOTES
Note: All timing references are nominal values. Refer to the electrical specifications for limits
Internal Timing – With external components as indicated on the application drawing the period of the
oscillator is 1.67 seconds in standby. Every 1.66 seconds the detection circuitry is powered up for
10.5mS and the status of the detect comparator is latched. In addition every 40 seconds the LED driver is
turned on for 10.5mS and the status of the low battery comparator is latched. The detect comparator
status is not checked during the low battery test, during the low battery horn warning chirp, or when the
horn is on due to an alarm condition.
If an alarm condition is detected the oscillator period increases to 41.5mS.
Due to the low currents used in the oscillator the capacitor on pin 12 should be a low leakage type.
Oscillator accuracy will depend mainly on the tolerance of the RBIAS resistor and OSCAP capacitor.
Alarm Circuit – The alarm comparator compares the alarm voltage to a voltage derived from a resistor
divider across VDD. . This divider voltage must be provided externally on pin 13 (VSEN). See the
application drawing (FIG 2). In an alarm condition the horn is turned on for 167mS and turned off for
87ms.
The guard amplifier and outputs are always active and will be within 50mV of the DETECT input. The
guard outputs also allow for measurement of the DETECT input without loading the sensing element.
Low Battery Detection – An internal reference is compared to the voltage divided VDD supply. The
battery can be checked under load via the LED low side driver output since low battery status is latched
at the end of the 10mS LED pulse. Pin 3 (LBADJ) can be used to modify the low battery set point by
placing a resistor to VDD or VSS.
LED Pulse – The LED is pulsed on for 10.5mS every 40S in standby. In alarm the LED is pulsed on for
10.5mS every 1S.
Testing – By holding pin 12 (OSCAP) low the internal power strobe is active and pins 1 (DETCOMP) and
4 (LBCOMP) can be used to check for alarm and low battery respectively. Please refer to the timing
diagrams.